Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2015;9(4): 216-220.
doi: 10.15171/joddd.2015.039
PMID: 26889357
PMCID: PMC4753029
  Abstract View: 1067
  PDF Download: 576

Original Research

Comparative Evaluation of the Effect of Manufacturing Process on Distortion of Rotary ProFile and Twisted File: An in Vitro SEM Study

Swati Sharma 1*, Rajendra Kumar Tewari 2, Pankaj Kharade 2, Pankaj Kharade 3

1 Senior Resident, Masters in Dental Surgery, Department of Conservative Dentistry and Endodontics, Dr. Z.A. Dental College, Aligarh Muslim University, Aligarh, India
2 Professor, Department of Conservative Dentistry and Endodontics, Dr. Z.A. Dental College, Aligarh Muslim University, Aligarh, India
3 Assistant Professor, Department of Prosthodontics, Dr. Z.A. Dental College, Aligarh Muslim University, Aligarh, India
*Corresponding Author: Email: drswatimds@yahoo.com

Abstract

Background and aims. The manufacturing process of rotary Ni-Ti file can influence its resistance to fracture. The rotary ProFile (Dentsply-Maillefer, Baillagues, Switzerland) is manufactured by grinding mechanism whereas Twisted File (Sy-bron Endo, USA) is manufactured with a twisting method. The purpose of this study was to comparatively evaluate the ef-fect of manufacturing process on distortion of rotary ProFile and Twisted files using scanning electron microscopy after in vitro use.Materials and methods. Five sets of each type of file were used for this study -rotary ProFile (group A) and Twisted file (group B). Each set was used according to manufacturer’s instructions to prepare 5 mesial canals of extracted mandibular molars. The changes in files were observed under a scanning electron microscope at ×18, ×100, ×250 and ×500 magnifica-tions. Observations were classified as intact with no discernible distortion, intact but with unwinding, and fractured. Group A and B were then compared for deformation and fracture using two-proportion z-test.Results. On SEM observation, used rotary ProFile showed microfractures along the machining grooves whereas Twisted file showed crack propagation that was perpendicular to the machining marks. On statistical analysis, no significant differ-ence was found between ProFile and Twisted file for deformation (P=0.642) and fracture (P=0.475).Conclusion. Within the experimental protocol of this study, it was concluded that both ProFile and Twisted files exhibited visible sign of distortion before fracture. But Twisted file gained edge over ProFile because of its manufacture design and unparalleled resistance to breakage.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1068

Your browser does not support the canvas element.


PDF Download: 576

Your browser does not support the canvas element.

Submitted: 19 Jan 2016
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)