Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2016;10(1): 17-22.
doi: 10.15171/joddd.2016.003
PMID: 27092210
PMCID: PMC4831606
  Abstract View: 849
  PDF Download: 621

Original Research

Sealing of adhesive systems in ferric sulfate-contaminated dentinal margins in class V composite resin restorations

Niloofar Shadman 1, Shahram Farzin Ebrahimi 1*, Najmeh Mollaie 2

1 Assistant Professor, Department of Operative Dentistry, Faculty of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
2 Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
*Corresponding Author: Email: s.farzinebrahimi@gmail.com

Abstract

Background. Hemostatic agents are applied to prepare an isolated bleeding-free condition during dental treatments and can influence adhesive restorations. This study evaluated the effect of a hemostatic agent (ViscoStat) on microleakage of contaminated dentinal margin of class V composite resin restorations with three adhesives.Methods. Sixty freshly extracted human molars were selected and class V cavities (3×3×1.5 mm) were prepared on buccal and lingual surfaces. Gingival margins of the cavities were placed below the cementoenamel junction. The teeth were divided into six groups randomly. The adhesives were Excite, AdheSE and AdheSE One. In three groups, the gingival walls of the cavities were contaminated with ViscoStat and then rinsed. The cavities were restored with composite resin and light-cured. After storage in distilled water (37°C) for 24 hours and polishing, the samples were thermocycled and sealed with nail varnish. Then they were stored in 1% basic fuchsin for 24 hours, rinsed and mounted in self-cured acryl resin, followed by sectioning buccolingually. Dye penetration was observed under a stereomicroscope and scored. Data were statistically analyzed with Kruskal-Wallis and Mann-Whitney U tests. P<0.05 was set as the level of significance.Results. Only in the Excite group, contamination did not have adverse effects on dentin microleakage (P > 0.05). In the contaminated groups, Excite had significantly less microleakage than the others (P = 0.003). AdheSE and AdheSE One did not exhibit significant difference in microleakage (P > 0.05).Conclusion. ViscoStat hemostatic agent increased dentinal microleakage in AdheSE and AdheSE One adhesives with no effect on Excite.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 850

Your browser does not support the canvas element.


PDF Download: 621

Your browser does not support the canvas element.

Submitted: 05 Apr 2016
Accepted: 07 Apr 2016
ePublished: 07 Apr 2016
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)