Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2017;11(2): 110-116.
doi: 10.15171/joddd.2017.020
PMID: 28748052
PMCID: PMC5519991
  Abstract View: 1712
  PDF Download: 1521
  Full Text View: 916

Clinical Dentistry

Original Article

The effect of repeated torque tightening on total lengths of implant abutments in different internal implant‒abutment connections

Fariba Saleh Saber 1,2, Nader Abolfazli 3, Soheil Jannatii Ataei 2, Mahsa Taghizade Motlagh 2, Vahede Gharekhani 2*

1 Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
2 Department of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
3 Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: Email: gharekhaniv8@gmail.com

Abstract

Background. Since the misfit of crown has an important role in clinical performance of implant-supported prostheses, and due to the impact of the settling effect on misfit, the aim of this study was to investigate the impact of torque forces on the total lengths of narrow and short implant abutments in different internal implant‒abutment connections. Methods. In four different implant‒abutment connections, 8 analog implants with a normal diameter (4 mm) and narrow abutment (4.5 mm) were selected from groups of internal hex, internal octagon, morse hex 6° and morse hex 11°. Each of them was mounted within plaster type IV, and 32 samples were obtained. Then, the amount of vertical displacement was measured by closing the impression copings and applying torques of 20 25 and 30 Ncm. This stage was repeated for the abutment. In the next stage, the resin pattern was built and measurements were performed after applying the torques mentioned. Finally, after making the frame, this stage was repeated, and the settling effect was statistically analyzed with ANOVA. Results. In the stages of impression coping, resin pattern and final prosthesis, HEXAGONE had significantly the highest and OCTAGONE had the lowest rates of settling, and the settling of morse hex 11° and 6° was between them. Conclusion. Octagon implant had significantly the lowest settling in various clinical and laboratory stages by applying different torques.

© 2017 Saleh Saber et al. This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Crea-tive Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1713

Your browser does not support the canvas element.


PDF Download: 1521

Your browser does not support the canvas element.


Full Text View: 916

Your browser does not support the canvas element.

Submitted: 23 Apr 2017
Accepted: 20 Jun 2017
ePublished: 21 Jun 2017
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)