Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2019;13(2): 98-102.
doi: 10.15171/joddd.2019.015
PMID: 31592105
PMCID: PMC6773915
  Abstract View: 1662
  PDF Download: 1035
  Full Text View: 570

Basic Research

Original Article

Effects of incorporation of silver and titanium nanoparticles on feldspathic ceramic toughness

Vasudevan Karthikeyan 1, Naveen Gopi Chander 2*, Jetti Ramesh Reddy 3, Balasubramanium Muthukumar 4

1 Senior Lecturer, Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, Chennai, India
2 Professor, Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, Chennai, India
3 Reader, Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, Chennai, India
4 Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, Chennai, India
*Corresponding Author: *Corresponding Author; E-mail: , Email: drgopichander@gmail.com

Abstract

Background. Porcelain is brittle and in many situations it requires replacement in fractured or chipped restorations. The prospects exist in improving the strength of feldspathic porcelain to widen its applications. This study evaluated the fracture toughness of feldspathic porcelain after incorporation of silver and titanium nanoparticles at varying concentrations (0.5 wt%, 1 wt%, 1.5 wt% and 2 wt%).

Methods. Test specimen dimensions were standardized to ASTM C1421–16 standards and a three-point flexure test was carried out to evaluate fracture toughness. A total of 330 samples were fabricated and broadly divided into three groups. Group I (titanium nanoparticles) and group II (silver nanoparticles) were further subdivided into 5 groups (0 wt%, 0.5 wt%, 1 wt%, 1.5 wt% and 2 wt%) for fracture toughness analysis, with each group consisting of 30 samples. Group III contained the superior concentration of both titanium and silver nanoparticles. The fracture toughness (KIC) was calculated using indentation fracture method and microstructure observations were made using scanning electron microscopy. The KIC values were compared and evaluated using one-way ANOVA.

Results. Data were analyzed using one-way ANOVA and Tukey’s HSD post hoc test multiple comparisons. The mean values of group I, group II and group III were 1.949 MPa.m1/2, 2.002 MPa.m1/2 and 1.330 MPa.m1/2 , respectively.

Conclusion. The results revealed that the samples reinforced with titanium and silver nanoparticles showed significant increases in fracture toughness. The blending of superior concentration of both titanium and silver nanoparticles decreased fracture resistance.

First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1663

Your browser does not support the canvas element.


PDF Download: 1035

Your browser does not support the canvas element.


Full Text View: 570

Your browser does not support the canvas element.

Submitted: 21 Oct 2018
Accepted: 07 Jul 2019
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)