Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2019;13(3): 177-182.
doi: 10.15171/joddd.2019.028
PMID: 31857863
PMCID: PMC6904917
  Abstract View: 1910
  PDF Download: 1209
  Full Text View: 642

Clinical Dentistry

Original Article

Comparison of the Hounsfield unit in CT scan with the gray level in cone-beam CT

Tahmineh Razi 1 ORCID logo, Parya Emamverdizadeh 2, Nadia Nilavar 1 ORCID logo, Sedigheh Razi 1* ORCID logo

1 Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
2 Department of Oral and Maxillofacial Pathology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: *Corresponding Author; E-mail: , Email: sed_razi@yahoo.com

Abstract

Background. The present study was undertaken to compare the Hounsfield Unit (HU) in computed tomography (CT) with the gray level in CBCT in human tissues.

Methods. In this study, 25 different soft and hard tissues were evaluated in 21 patients. CBCT images were taken with Newtom VGi machine (Verona, Italy) and CT images were prepared with Somatom Sensation unit (Siemens, Germany). The HU values of soft and hard tissues were compared with the gray level values of CBCT images.

Results. There was a strong correlation between the HU in CT and the gray level in CBCT in soft tissues (P<0.001, R2=0.85) and hard tissues (P<0.001, R2=0.74) and in general (P<0.001, R2=0.91).

Conclusion. A high degree of agreement was seen between HU in CT and gray level in CBCT in both hard and soft tissues. Since the gray level in CBCT was similar to HU in CT and can be used as a parameter determine bone density in implant treatment and also to determine the bone type, the CBCT technique is recommended in such cases due to its low radiation dose, short time and low cost compared to CT.

First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1882

Your browser does not support the canvas element.


PDF Download: 1209

Your browser does not support the canvas element.


Full Text View: 642

Your browser does not support the canvas element.

Submitted: 11 Dec 2018
Accepted: 23 May 2019
ePublished: 05 Dec 2019
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)