Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2021;15(2): 106-110.
doi: 10.34172/joddd.2021.018
PMID: 34386181
PMCID: PMC8346716
Scopus ID: 85118419953
  Abstract View: 1233
  PDF Download: 709
  Full Text View: 277

Basic Research

Original Article

Biomechanical behavior of atrophic maxillary restorations using the all-on-four concept and long trans-sinus implants: A finite element analysis

Liliane Pacheco de Carvalho 1, Alexandre Marcelo de Carvalho 2*, Carlos Eduardo Francischone 3, Flavia Lucisano Botelho do Amaral 3, Bruno Salles Sotto-Maior 4 ORCID logo

1 Department of Prosthodontics, Faculty of Dentistry UNIFAGOC Institute and Research Center, Brazil
2 Department of Periodontology, Faculty of Dentistry UNIFAGOC Institute and Research Center, Brazil
3 Department of Implantology, Faculty of Dentistry, Dental Research Center of São Leopoldo Mandic, Brazil
4 Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Juiz de Fora, Brazil
*Corresponding Author: *Corresponding author: Alexandre Marcelo de Carvalho, Email: , Email: bruno.sotto@ufjf.edu.br

Abstract

Background. Maxillary bone atrophy with a considerable amount of pneumatization and anterior expansion of the maxillary sinus might be a situation limiting oral rehabilitation with osseointegrated implants. Therefore, the present study aimed to biomechanically evaluate two rehabilitation techniques for maxillary bone atrophy: all-on-four and long trans-sinus implants.

Methods. Two three-dimensional models consisting of atrophic maxilla with four implants were simulated. In the M1 model, two axially inserted anterior implants and two tilted implants, 15 mm in length, placed tangential to the maxillary sinus’s anterior wall were used. In the M2 model, two axially inserted anterior implants and two trans-sinus tilted implants, 24 mm in length, were used. For the finite element analysis (FEA), an axial load of 100 N was applied on the entire extension of the prosthesis, simulating a rehabilitation with immediate loading. The peri-implant bone and the infrastructure were analyzed according to the Mohr-Coulomb and Rankine criteria, respectively.

Results. The results were similar when the stresses on peri-implant bone were compared: 0.139 and 0.149 for models 1 and 2, respectively. The tension values were lower in the model with trans-sinus implants (27.99 MPa).

Conclusion. It was concluded that the two techniques exhibited similar biomechanical behavior, suggesting that the use of long trans-sinus implants could be a new option for atrophic maxilla rehabilitation.


First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1234

Your browser does not support the canvas element.


PDF Download: 709

Your browser does not support the canvas element.


Full Text View: 277

Your browser does not support the canvas element.

Submitted: 14 Jun 2020
Accepted: 21 Jan 2021
ePublished: 05 May 2021
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)