Logo-joddd
J Dent Res Dent Clin Dent Prospects. 2021;15(4): 226-231.
doi: 10.34172/joddd.2021.037
PMID: 35070174
PMCID: PMC8760375
Scopus ID: 85125638571
  Abstract View: 1342
  PDF Download: 749
  Full Text View: 340

Original Article

Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period

Gulsum Sayin Ozel 1* ORCID logo, Ozgur Inan 2, Asli Secilmis Acar 3, Gamze Alniacik Iyidogan 4, Dogan Dolanmaz 5, Gulsun Yildirim 6

1 Department of Prosthodontics, Istanbul Medipol University, Istanbul, Turkey
2 Department of Prosthodontics, Selcuk University, Konya, Turkey
3 Department of Prosthodontics, Gaziantep University, Gaziantep, Turkey
4 Department of Prosthodontics, Mersin Dental Hospital, Mersin, Turkey
5 Department of Oral Maxillofacial Surgery, Bezmialem University, Istanbul, Turkey
6 Department of Oral Maxillofacial Surgery, Alaaddin Keykubat University, Antalya, Turkey
*Corresponding Author: *Corresponding author: Gulsum Sayin Ozel, Email: , Email: gozel@medipol.edu.tr

Abstract

Background. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA).

Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n=25) or modified (SLActive) surface properties (n=25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time.

Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P<0.05). Stability improved each week except in the 4th week in SLActive surface measurements. No significant differences were observed between the groups at 2 and 3 months (P>0.05).

Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups.




First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1343

Your browser does not support the canvas element.


PDF Download: 749

Your browser does not support the canvas element.


Full Text View: 340

Your browser does not support the canvas element.

Submitted: 05 Jun 2020
Accepted: 09 Sep 2020
ePublished: 05 Dec 2021
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)