Logo-joddd
J Dent Res Dent Clin Dent Prospects. 17(4):235-241. doi: 10.34172/joddd.2023.40589

Original Article

Marginal adaptation of different monolithic zirconia crowns with horizontal and vertical finish lines: A comparative in vitro study

Mohammed Qasim Nasir Conceptualization, Formal analysis, Investigation, Methodology, Resources, Writing – original draft, Writing – review & editing, * ORCID logo
Alaa Jawad kadhim Data curation, Project administration, Supervision, Validation, Writing – original draft, Writing – review & editing, ORCID logo

Author information:
Department of Restorative and Aesthetic Dentistry, College of Dentistry, University of Baghdad, Baghdad, Iraq

*Corresponding author: Mohammed Qasim Nasir, Email: Mohammed.Qasem1204a@codental.uobaghdad.edu.iq

Abstract

Background.

This study evaluated the influence of different tooth preparation techniques and zirconia materials on marginal adaptation.

Methods.

Forty-eight healthy human maxillary first premolars were divided into two primary groups based on preparation design: group A (chamfer) and group B (vertical). Within each main group, there were three subgroups, comprising eight teeth each, distinguished by the type of zirconia material employed (Zircad LT, MT, and Prime by Ivoclar Vivadent). All the samples were prepared by the same operator using a dental surveyor. Intraoral scanning was performed on the prepared teeth. SironaInLab CAD 20.0 software was used to design crowns, which were subsequently generated using a 5-axis milling machine. The crowns were cemented to their respective teeth with self-adhesive resin cement. Marginal gap measurements were taken in micrometers (μm) before and after cementation at 16 sites per sample using a digital microscope at×230 magnification. The collected data were evaluated using statistical analysis using the independent t-test, paired t-test, and ANOVA at an 0.05 significance level.

Results.

The vertical preparation group exhibited the smallest marginal gap, while the chamfer group displayed the largest. This disparity was statistically significant (P<0.05) for pre- and post-cementation measurements across all materials. There were no significant differences between the different monolithic zirconia crowns.

Conclusion.

The vertical preparation design illustrated significantly better marginal adaptation than the chamfer preparation design. Comparisons between materials showed comparable marginal gaps. The mean values of the marginal gaps in all groups increased significantly after cementation.

Keywords: Chamfer, Marginal gap, Monolithic, Vertical, Zirconia

Copyright and License Information

©2023 The Author(s).
This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited.

Introduction

All-ceramic restorations have gained popularity in dentistry because of their enhanced biocompatibility and esthetics.1

The marginal gap between the restoration and the prepared tooth causes bacterial aggregation, periodontal issues, recurrent caries, and restoration failure.2 Misfit, on the other hand, was found to reduce the fracture strength of ceramic restorations.3

The tooth preparation design is an important component in the marginal accuracy and fracture strength of the restoration. As a result, the geometry and amount of tooth reduction should reduce stress and provide the best marginal fit to protect the health of the surrounding tissue and maximize the longevity of the restoration.4

Since zirconia is opaque, it is frequently coated with porcelain in clinical conditions.5 Monolithic zirconia restorations have been introduced as an alternative to mitigate veneering porcelain chipping.6 The development of translucent zirconia materials, known as monolithic translucent zirconia, has overcome the poor optical characteristics of traditional zirconia.5 Traditional horizontal preparation with shoulder finish lines and chamfer has been the norm or standard for all-ceramic restorations. On the other hand, these preparations are invasive and require the removal of intact tooth structure, which is unfavorable for biological and aesthetic reasons.7 With the emergence of high-strength polycrystalline materials, vertical preparation has been proposed as an alternative that is less invasive than horizontal preparation.8

Therefore, this research study examined the marginal adaptation of different monolithic zirconia materials in horizontal and vertical preparation techniques. The null hypothesis posited that the type of zirconia and preparation technique would not significantly affect marginal adaptation.


Methods

Forty-eight human maxillary first premolars chosen for this study were extracted from orthodontic patients aged 18‒22. Using G*Power 3.1.9.7 (a program developed by Franz-Faul at the University of Kiel in Germany), the sample size was determined with the following parameters: the power of the study = 95%, alpha error of probability = 0.05, a statistical test of analysis of variance, the effect size of F = 0.31, number of groups = 6, etc. With all these parameters met, the sample size was n = 42 plus a 10% error rate, making 48 samples sufficient for this study. To minimize variables, the teeth were evaluated for crown size using a digital caliper9 and evaluated using a digital microscope (Dino-Lite Capture 2.0, version 1.3.6., Taiwan) at × 40 magnification to exclude any teeth with caries, restorations, or cracks. The use of extracted human teeth was ethically approved by the Research Ethics Committee of the College of Dentistry, University of Baghdad (Project No.: 503522, Ref. No.: 503). To prevent fungal and bacterial infection, thymol solution is used at room temperature for one week,10 followed by immersion in distilled water to prevent the teeth from dehydration.11

The individual teeth were placed in a custom-made square rubber mold measuring 2.0 cm in height, 1.5 cm in length, and 1.5 cm in width, filled with freshly mixed cold-cured acrylic resin. Next, a dental surveyor was used to ensure that each tooth was vertically aligned with the mold’s horizontal plane. To mimic the support of healthy alveolar bone, the teeth were embedded 2 mm apical to the cementoenamel junction (CEJ).12 The teeth were then categorized into two groups of 24, based on one of the preparation techniques (horizontal or vertical).

Group A: Horizontally prepared teeth (chamfer finish line)

Group B: Vertically prepared teeth

Then, based on the type of material, each main group was subcategorized into three subgroups of eight teeth.

Subgroup 1: Monolithic zirconia (IPS e.maxZirCAD LT) (IvoclarVivadent: Schaan, Liechtenstein)

Subgroup 2: Monolithic zirconia (IPS e.maxZirCAD MT) (IvoclarVivadent: Schaan, Liechtenstein)

Subgroup 3: Monolithic zirconia (IPS e.max ZirCAD Prime) Ivoclar Vivadent: Schaan, Liechtenstein)

For standardization, a dental surveyor was used to prepare all the samples (Figure 1). The surveyor’s vertical arm was adjusted to hold a high-speed handpiece (Foshan Shengling Medical Apparatus, China) to ensure parallelism between the bur’s long axis and the tooth’s long axis, verified with a protractor.13 All teeth were prepared with an axial height of 4 mm measured from the mesial surface to the finish line 1 mm above the CEJ. The chamfer margin design (0.8 mm in depth) for group A teeth was prepared with a round-end tapered fissure diamond bur (6856 314 016, Komet, Germany) with a total convergence angle of 6º (Figure 2).

joddd-17-235-g001
Figure 1.

Preparation of teeth using a modified dental surveyor


joddd-17-235-g002
Figure 2.

Prepared tooth sample from group A


In group B, the vertical margin was prepared using a round-end tapered diamond bur (851-012C-FG, NTI, Germany) with a 4º total convergence angle (Figure 3). The barrel-shaped trapezoid diamond bur (811LG.314.037, VERDANT, Poland) was used for planar occlusal reduction of approximately 1.5–2 mm in both groups. A digital caliper was used to check all measurements.

joddd-17-235-g003
Figure 3.

Prepared tooth sample from group B


CEREC Omnicam intraoral scanner (Sirona, Germany) was used to take a digital impression for every tooth. The crowns were then machined out of zirconia blanks (IPS e.max ZirCAD LT, MT, and Prime; Ivoclar Digital, Germany) with a 5-axis milling unit (In-Laboratory MC 5 Milling Machine, Sirona, Germany) using Sirona inLab CAD 20.0 software. The milled crowns were sintered at 1500 °C in an InFire HTC Speed Sintered Furnace (Sirona, Germany) to keep their original color, strength, and size.

Glaze paste (FLUO Ivocolor; Ivoclar Vivadent, Liechtenstein) was used to brush the crowns. The glaze firing/crystallization was performed in the Programat P500 furnace (Ivoclar, Germany) at 710 °C for 18 minutes. The interior surfaces of all crown restorations were sandblasted for 15 seconds with 1 bar at a distance of 10 mm and aluminum oxide particles measuring ≤ 50 μm to create a rough and retentive surface with a sandblasting machine (Renfert, Germany) to promote mechanical interlocking between the luting and zirconia.14

The vertical marginal gap for every crown was determined by employing a Dino-lite digital microscope at × 230 magnification and ImageJ software, which corresponded with the marginal gap definition byHolmes et al15: “perpendicular distance from the margin of the restoration to the margin of the tooth preparation.” Mid-buccal, mid-mesial, mid-distal, and mid-palatal were the four points on each surface of the specimen where the measurement was taken” (Figure 4). For each sample, sixteen measurements were taken, and the mean of all these measurements was calculated to represent the pre-cementation marginal gap (Figure 5). The same operator performed each measurement three times to reduce errors as much as possible.16,17

joddd-17-235-g004
Figure 4.

Points of measurement for the marginal gap


joddd-17-235-g005
Figure 5.

Measurement of marginal gaps by a digital microscope attached to a computer


The digital microscope was used to capture a snapshot of 1 mm of a ruler at a zoom of 230x to convert these measurements from “pixels” to “micrometers” for image calibration. The image was then opened in the ImageJ program, and a (straight line) tool was used to create a line corresponding to a known distance of 1 mm. The analyze option was then selected from the main menu at the same microscope calibration and magnification, and the set scale was opened to convert all calculated pixel readings to “μm.”18 The known distance was entered into the dialog, along with the unit of measurement (1000 and μm, respectively). The pixel section was filled in automatically with a distance defined by the length of the selected line19 (Figure 6).

joddd-17-235-g006
Figure 6.

Calibration process of the ImageJ software


The marginal gap was measured after cementation following the same procedures as the pre-cementation measurement. The crowns were subsequently attached to their respective teeth with a self-adhesive resin cement (TheraCem BISCO, USA). Finger pressure was used for seating the crown before a 5-kg vertical load was applied for 6 minutes with a (custom-made cementation apparatus).20 All the samples were immersed and kept in distilled water at 37 °C for one day (24 h).21

Statistical evaluation was performed using SPSS 27. The Shapiro-Wilk test was utilized to evaluate the variables’ normal distribution. ANOVA was utilized to determine the significance of the mean difference in fracture strength within groups. An independent t-test was used to determine the significance of the fracture strength mean difference between groups.


Results

The results of the Shapiro-Wilk test demonstrated that the data were distributed normally with a P value < 0.05. Table 1 presents descriptive data such as means and maximum and minimum vertical marginal gaps in (μm) for the two groups and their subgroups pre- and post-cementation, including standard deviation. Pre-cementation, subgroup B1 (vertical preparation design, ZirCAD LT material), had the lowest mean value of marginal gap (16.123 μm). In comparison, the highest mean value of marginal gap (25.159 μm) was recorded in subgroup A2 (chamfer preparation design, ZirCAD MT material).


Table 1. Descriptive statistics of the vertical marginal gap in (μm)
Main group (A) Chamfer preparation (B) Vertical preparation
Subgroup (A1) LT (A2) MT (A3) Prime (B1) LT (B2) MT (B3) Prime
Pre-cementation marginal gap
Min 20.294 21.897 20.65 14.294 15.212 14.863
Max 28.063 27.196 28.533 18.034 18.266 17.785
Mean 23.641 25.159 23.814 16.123 16.360 16.382
SD 2.851 1.801 2.491 1.572 1.166 0.973
Post-cementation marginal gap
Min 34.719 34.172 33.326 24.691 25.369 22.148
Max 37.358 38.165 36.891 29.752 29.863 28.898
Mean 36.022 36.833 35.450 27.700 28.116 26.689
SD 0.775 1.309 1.319 1.671 1.471 2.230

Meanwhile, there is a general increase in the mean values of the marginal gap among all groups post-cementation. Subgroup B3 (vertical preparation design, ZirCAD Prime material) exhibited the lowest mean value of the marginal gap (26.689 μm), while the highest mean value of the marginal gap (36.833 μm) was recorded in subgroup A2 (chamfer preparation design, MT material).

The marginal gap was compared between the groups by performing an independent t-test at a significance of 0.05, as shown in Tables 2 and 3. The results of the current study demonstrated a statistically significant difference in both pre - and post-cementation marginal gap between both groups (P < 0.05).


Table 2. Independent t-test for comparing the marginal gaps between groups (effect of preparation design) pre-cementation
Subgroups Mean difference t-value Df P value
A1 B1 7.518 6.531 14 0.000
A2 B2 8.799 11.599 14 0.000
A3 B3 7.432 7.861 14 0.000

Table 3. Independent t-test for comparing the marginal gaps between groups (effect of the preparation design) post-cementation
Subgroups Mean difference t-value Df P value
A1 B1 8.321 12.779 14 0.000
A2 B2 8.716 12.519 14 0.000
A3 B3 8.761 9.566 14 0.000

ANOVA with a significance level of 0.05 was carried out to compare the marginal gap within a group, as shown in Tables 4 and 5. Within both main groups, no significant differences were identified in both pre- and post-cementation marginal gaps.


Table 4. One-way ANOVA for comparing the marginal gaps within groups (effect of the material type) pre-cementation
Groups Sum of squares df Mean square F P value
A (A1-A2-A3) Between groups 11.050 2 5.525 0.943 0.405
Within groups 123.048 21 5.859
Total 134.098 23
B (B1-B2-B3) Between groups 0.329 2 0.164 0.103 0.902
Within groups 33.435 21 1.592
Total 33.763 23

Table 5. One-way ANOVA test for comparison of the marginal gap within groups (effect of the material type) post-cementation
Groups Sum of squares df Mean square F P value
A (A1-A2-A3) Between groups 7.724 2 3.862 2.858 0.080
Within groups 28.379 21 1.351
Total 36.103 23
B (B1-B2-B3) Between groups 8.620 2 4.310 1.303 0.293
Within groups 69.490 21 3.309
Total 78.110 23

Paired t-test was used to determine any significant difference in mean values of marginal gaps post- and pre-cementation within each subgroup, as shown in Table 6. There were significant differences in each subgroup between post- and pre-cementation marginal gaps (P < 0.05).


Table 6. Paired t-test for comparing the pre- and post-cementation marginal gaps in (μm)
Subgroups Mean difference t-value df P value
A1 Post‒pre-cementation 12.381 10.032 7 0.000
A2 Post‒pre-cementation 11.674 18.905 7 0.000
A3 Post‒pre-cementation 11.636 16.572 7 0.000
B1 Post‒pre-cementation 11.577 21.561 7 0.000
B2 Post‒pre-cementation 11.756 16.819 7 0.000
B3 Post‒pre-cementation 10.308 12.983 7 0.000

Discussion

The demand for minimally invasive dentistry has led to the introduction of vertical preparation as a less intrusive approach to tooth structure restoration.7 To ensure standardization in production, all crowns were fabricated using the same designing software (inLab CAD 20.0), restoration parameters, and a 5-axis milling machine (inLab MC X5), which offers better marginal accuracy compared to a 4-axis milling machine.22

A finishing line with a chamfer preparation design was used for horizontal preparation because many studies have shown that it produces better marginal accuracy than a shoulder finish line.16,23 For all prepared teeth, a planar occlusal reduction was used to minimize tooth structure removal, compromising tooth vitality.4 A digital microscope was used to measure the marginal gap because it is a non-destructive, direct method that does not damage the specimens. This method was also clinically applicable and the most commonly used method for measuring the vertical gap.14,17,24

The most popular and clinically applicable technique for assessing the suitability of crown restorations has been considered the vertical marginal gap evaluation.25 The clinically acceptable vertical gap for CAD/CAM-fabricated restorations has been reported to range between 17 and 118 m.20,26 In this study, all vertical marginal gaps post- and pre-cementation measurements were within the clinically acceptable range.

There was no significant difference between groups (no effect of material type) for both preparation designs, which can be attributed to the fact that all materials were from the same manufacturer and used the same parameters provided by the manufacturer, the same fabrication process (ZirCAD Labside Instructions for Use, Ivoclar, 2021), and the same CAD/CAM system and scanner. These findings are consistent with those of Att et al,27 who concluded that the manufacturing technique influences the marginal accuracy of CAD/CAM prostheses. According to a study,22,28 the CAD/CAM system affected the marginal adaptation of all-ceramic crowns fabricated using the CAD/CAM technology. Another study discovered a significant difference in accuracy between the tested intraoral scanners.29

The chamfer preparation design recorded a higher pre- and post-cementation marginal gap, with a significant difference from the vertical preparation design, which recorded a lower marginal gap. This may be explained by the restoration margin being closer to the teeth when it has an acute angle at its end.30

A larger gap with the chamfer finish line was most likely caused by its design, which may not have been properly scanned, resulting in less adaptation.31

A chamfer finish line’s curved (concave and convex) surfaces may make it more difficult to mill the crown restoration, which would reduce the marginal fit.32

The subtractive milling process is limited by the milling bur’s restricted size and shape. As a result, small details of concave shape cannot be milled with high precision.33

The same findings have been reported by Comlekoglu et al34 and Almahdy et al,35 concluding that monolithic zirconia constructed with feather edge margins has better marginal accuracy than deep chamfer margin designs.

On the other hand, Cetik et al36 discovered a comparable internal and marginal adaptation with the chamfer and knife-edge margins in their SEM study, which both yielded better adaptation results than the shoulder.

Eldamaty et al37 discovered no statistically significant differences in the marginal accuracy of monolithic zirconia crowns with chamfer and vertical margins. However, they used metal dies instead of natural teeth as abutments used in the present study.

Since both the cementation process and the cement play a significant role in the final discrepancy of the restoration, a marginal gap measurement of the restoration without cement cannot be considered clinically relevant.38 The marginal gap results after cementation showed a significantly higher mean value than before cementation, regardless of margin design. Other studies have found that cementation increases the vertical marginal gap significantly.16,17,38 This could be due to the hydraulic pressure created during cementation, which could push the cement upward.38 Another possible explanation is that the marginal spacer in the CAD/CAM system’s designing software was set to “zero,” while the radial and occlusal spacers were set to “100 µm” beginning 1 mm above the preparation margin. As a result, as the crown approaches its final position, there is no space for cement’s escape through the cervical marginal collar, resulting in a large amount of luting cement accumulating on the occlusal surface of the prepared tooth, potentially interfering with proper crown seating and increasing the marginal discrepancy.39 A 25-µm spacer at the marginal area of the finishing line reduces marginal and internal gaps in comparison with using zero cement space at the marginal area.40

In contrast, other studies revealed that cementation did not significantly increase zirconia crowns’ vertical marginal discrepancy.27,41,42 The various parameters, such as the cement type, cement volume, and seating force used during cementation, may account for these conflicting findings.

This study was carried out in vitro with natural teeth as the substrate. Natural teeth vary in size, form, and structure. Even though in vitro studies can provide controlled conditions, other aspects associated with the aging of the restoration, such as low-temperature degradation and stress-induced toughening of zirconia, which may alter the restoration behavior intraorally, were not investigated due to the in vitro experimental settings. Although measuring the marginal gap is regarded as the gold standard for assessing the adaptability of the restoration, it does not reflect the overall seating of the restoration, so measuring the internal gap is still necessary. It is also necessary to study the fracture strengths and marginal adaptations of monolithic zirconia crowns using different cement spacers, different types of cement, and different margin thicknesses.


Conclusion

In summary, based on the drawbacks associated with this in vitro study, four main conclusions are made.

  1. The mean values of the marginal gap of zirconia crowns in all the groups were within the clinically acceptable range.

  2. The mean values of the marginal gap of zirconia crowns in all the groups increased significantly after cementation.

  3. The vertical preparation design resulted in a significantly lower marginal gap than the chamfer preparation design.

  4. Materials’ comparisons within both preparation designs revealed comparable marginal gap results.

The above conclusions suggest using vertical preparation as a minimally invasive alternative to horizontal preparation for monolithic zirconia crowns.


Acknowledgments

We would like to acknowledge the support of the Department of Restorative and Aesthetic Dentistry, College of Dentistry, University of Baghdad, Iraq, for providing the necessary resources and facilities for this research.


Competing Interests

The authors declare no conflicts of interest related to this research.


Ethical Approval

The research project with project No. 503522 received ethical approval from the Research Ethics Committee of the College of Dentistry, University of Baghdad (Ref. number: 503) on March 10, 2022.


Funding

No external funding was received for this study.


References

  1. Beuer F, Stimmelmayr M, Gueth JF, Edelhoff D, Naumann M. In vitro performance of full-contour zirconia single crowns. Dent Mater 2012; 28(4):449-56. doi: 10.1016/j.dental.2011.11.024 [Crossref] [ Google Scholar]
  2. Tsirogiannis P, Reissmann DR, Heydecke G. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis. J Prosthet Dent 2016;116(3):328-35.e2. 10.1016/j.prosdent.2016.01.028.
  3. Zahran MH. Factors Affecting the Fracture Strength and Fatigue Resistance of Molar Crowns Produced Using a Zirconia-Based System [dissertation]. University of Toronto; 2013.
  4. Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013;110(6):447-54.e10. 10.1016/j.prosdent.2013.08.003.
  5. Zhang Y. Making yttria-stabilized tetragonal zirconia translucent. Dent Mater 2014; 30(10):1195-203. doi: 10.1016/j.dental.2014.08.375 [Crossref] [ Google Scholar]
  6. Mitov G, Anastassova-Yoshida Y, Nothdurft FP, von See C, Pospiech P. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns. J Adv Prosthodont 2016; 8(1):30-6. doi: 10.4047/jap.2016.8.1.30 [Crossref] [ Google Scholar]
  7. Ramos RM, Clark D, Mazza M, Venuti P, Maiolino M, Kopanja S. The shoulderless approach: a new rationale in prosthetic dentistry. Tomorrow Tooth J 2017; 1:1-29. [ Google Scholar]
  8. Schmitz JH, Cortellini D, Granata S, Valenti M. Monolithic lithium disilicate complete single crowns with feather-edge preparation design in the posterior region: a multicentric retrospective study up to 12 years. Quintessence Int. 2017:601-8. 10.3290/j.qi.a38678.
  9. Taha NA, Palamara JE, Messer HH. Cuspal deflection, strain and microleakage of endodontically treated premolar teeth restored with direct resin composites. J Dent 2009; 37(9):724-30. doi: 10.1016/j.jdent.2009.05.027 [Crossref] [ Google Scholar]
  10. Sandhu SV, Tiwari R, Bhullar RK, Bansal H, Bhandari R, Kakkar T. Sterilization of extracted human teeth: a comparative analysis. J Oral Biol Craniofac Res 2012; 2(3):170-5. doi: 10.1016/j.jobcr.2012.09.002 [Crossref] [ Google Scholar]
  11. da Silva GR, da Silva NR, Soares PV, Costa AR, Fernandes-Neto AJ, Soares CJ. Influence of different load application devices on fracture resistance of restored premolars. Braz Dent J 2012; 23(5):484-9. doi: 10.1590/s0103-64402012000500003 [Crossref] [ Google Scholar]
  12. Taha NA, Palamara JE, Messer HH. Fracture strength and fracture patterns of root-filled teeth restored with direct resin composite restorations under static and fatigue loading. Oper Dent 2014; 39(2):181-8. doi: 10.2341/13-006-l [Crossref] [ Google Scholar]
  13. Hmedat SJ, Ibraheem AF. An in vitro evaluation of fit of the crowns fabricated by zirconium oxide-based ceramic CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Baghdad Coll Dent 2013; 25(1):43-8. [ Google Scholar]
  14. Abdulazeez MI, Majeed MA. Fracture strength of monolithic zirconia crowns with modified vertical preparation: a comparative in vitro study. Eur J Dent 2022; 16(1):209-14. doi: 10.1055/s-0041-1735427 [Crossref] [ Google Scholar]
  15. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62(4):405-8. doi: 10.1016/0022-3913(89)90170-4 [Crossref] [ Google Scholar]
  16. Abdullah LS, Ibraheem AF. The effect of finishing line designs and occlusal surface reduction schemes on vertical marginal fit of full contour CAD/CAM zirconia crown restorations (a comparative in vitro study). Int J Dent Oral Health 2017; 4(1):1-6. doi: 10.16966/2378-7090.247 [Crossref] [ Google Scholar]
  17. Abdulla HA, Majeed MA. Assessment of bioactive resin-modified glass ionomer restorative as a new CAD/CAM material Part I: marginal fitness study. Indian J Forensic Med Toxicol 2020; 14(1):865-70. doi: 10.37506/v14/i1/2020/ijfmt/193012 [Crossref] [ Google Scholar]
  18. Romeo E, Iorio M, Storelli S, Camandona M, Abati S. Marginal adaptation of full-coverage CAD/CAM restorations: in vitro study using a non-destructive method. Minerva Stomatol 2009; 58(3):61-72. [ Google Scholar]
  19. Ng J. A Comparison of Crown Marginal Fit Fabricated Using Digital and Conventional Methods [dissertation]. University of British Columbia; 2013.
  20. Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005; 93(4):346-55. doi: 10.1016/j.prosdent.2005.02.003 [Crossref] [ Google Scholar]
  21. Shahrbaf S, van Noort R, Mirzakouchaki B, Ghassemieh E, Martin N. Fracture strength of machined ceramic crowns as a function of tooth preparation design and the elastic modulus of the cement. Dent Mater 2014; 30(2):234-41. doi: 10.1016/j.dental.2013.11.010 [Crossref] [ Google Scholar]
  22. Ibraheem AF, Abdulkareem AM. Comparison of the marginal fitness of the ceramic crowns fabricated with different CAD/CAM systems (an in vitro study). J Baghdad Coll Dent 2016; 28(4):28-33. [ Google Scholar]
  23. Podhorsky A, Rehmann P, Wöstmann B. Tooth preparation for full-coverage restorations-a literature review. Clin Oral Investig 2015; 19(5):959-68. doi: 10.1007/s00784-015-1439-y [Crossref] [ Google Scholar]
  24. Mahdi AS, Majeed MA. Marginal fitness of monolithic zirconia crowns fabricated from direct digital scanning, impression scanning & indirect digital scanning using different impression materials (an in vitro study). Indian J Public Health Res Dev 2019; 10(11):1-10. [ Google Scholar]
  25. Wolfart S, Wegner SM, Al-Halabi A, Kern M. Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation. Int J Prosthodont 2003; 16(6):587-92. [ Google Scholar]
  26. Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J 2008; 27(3):422-6. doi: 10.4012/dmj.27.422 [Crossref] [ Google Scholar]
  27. Att W, Komine F, Gerds T, Strub JR. Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. J Prosthet Dent 2009; 101(4):239-47. doi: 10.1016/s0022-3913(09)60047-0 [Crossref] [ Google Scholar]
  28. Song TJ, Kwon TK, Yang JH, Han JS, Lee JB, Kim SH. Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems. J Adv Prosthodont 2013; 5(3):219-25. doi: 10.4047/jap.2013.5.3.219 [Crossref] [ Google Scholar]
  29. Falih MY, Majeed MA. Trueness and precision of eight intraoral scanners with different finishing line designs: a comparative in vitro study. Eur J Dent. 2022. 10.1055/s-0042-1757568.
  30. Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of Fixed Prosthodontics. Chicago, IL: Quintessence Publishing Company; 1997.
  31. Jalalian E, Naser Mostofi S, Shirian AA, Shamshirgar F, Kaseb Ghane H, Naseri M. Effect of sloped shoulder and deep chamfer finish lines on marginal adaptation of zirconia restorations. J Res Med Dent Sci 2018; 6(1):369-73. doi: 10.5455/jrmds.20186160 [Crossref] [ Google Scholar]
  32. Atlas A, Isleem W, Bergler M, Fraiman HP, Walter R, Lawson ND. Factors affecting the marginal Fit of CAD-CAM restorations and concepts to improve outcomes. Curr Oral Health Rep 2019; 6(4):277-83. doi: 10.1007/s40496-019-00245-2 [Crossref] [ Google Scholar]
  33. Li R, Chen H, Wang Y, Zhou Y, Shen Z, Sun Y. Three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition. J Prosthodont Res 2020; 64(4):478-84. doi: 10.1016/j.jpor.2020.01.002 [Crossref] [ Google Scholar]
  34. Comlekoglu M, Dundar M, Ozcan M, Gungor M, Gokce B, Artunc C. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent 2009; 34(5):586-92. doi: 10.2341/08-076-l [Crossref] [ Google Scholar]
  35. Almahdy RM, Mandour MH, El Sharkawy ZR. Marginal Accuracy of Monolithic Zirconia Crowns with Vertical and Horizontal Margin Configurations after Thermomechanical Fatigue. Al-Azhar Dent J Girls 2022; 9(1):55-60. doi: 10.21608/adjg.2021.63755.1340 [Crossref] [ Google Scholar]
  36. Cetik S, Bahrami B, Fossoyeux I, Atash R. Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study. J Adv Prosthodont 2017; 9(3):208-16. doi: 10.4047/jap.2017.9.3.208 [Crossref] [ Google Scholar]
  37. Eldamaty M, Abdel-Aziz M, El-Kouedi A, Hamza T. Effect of finish line design and cement space thickness on the marginal accuracy of monolithic zirconia crowns. Braz Dent Sci 2020; 23(3):1-8. doi: 10.14295/bds.2020.v23i3.1908 [Crossref] [ Google Scholar]
  38. Borges GA, Faria JS, Agarwal P, Spohr AM, Correr-Sobrinho L, Miranzi BA. In vitro marginal fit of three all-ceramic crown systems before and after cementation. Oper Dent 2012; 37(6):641-9. doi: 10.2341/11-012-l [Crossref] [ Google Scholar]
  39. Coelho Santos MJ, Navarro MF, Tam L, McComb D. The effect of dentin adhesive and cure mode on film thickness and microtensile bond strength to dentin in indirect restorations. Oper Dent 2005; 30(1):50-7. [ Google Scholar]
  40. Hammond ED, Ibraheem AF. Evaluate and compare the effect of different marginal cement space parameter setting in the CAD software on the marginal and internal fitness of monolithic zirconia crowns with different types of luting agents (a comparative in vitro study). J Res Med Dent Sci 2020; 8(1):74-80. [ Google Scholar]
  41. Gonzalo E, Suárez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009; 102(6):378-84. doi: 10.1016/s0022-3913(09)60198-0 [Crossref] [ Google Scholar]
  42. El-Dessouky RA, Salama MM, Shakal MA, Korsel AM. Marginal adaptation of CAD/CAM zirconia-based crown during fabrication steps. Tanta Dent J 2015; 12(2):81-8. doi: 10.1016/j.tdj.2014.12.002 [Crossref] [ Google Scholar]
Submitted: 14 Aug 2023
Accepted: 25 Oct 2023
First published online: 30 Dec 2023
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - FireFox Plugin)

Abstract View: 356
PDF Download: 367
Full Text View: 8