Logo-joddd
J Dent Res Dent Clin Dent Prospects. 18(3):172-181. doi: 10.34172/joddd.41227

Original Article

Effect of hydrothermal aging on color stability and translucency of two zirconia generations compared to lithium disilicate ceramics

Atef Ahmed Elzoughary Data curation, Formal analysis, Investigation, Methodology, Writing – original draft, * ORCID logo
Tamer Abel Rahim Hamza Conceptualization, Formal analysis, Validation, Writing – review & editing, ORCID logo
Mohamed Fawzy Metwally Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Validation, Writing – review & editing, ORCID logo

Author information:
Department of Crown and Bridge, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt

*Corresponding author: Atef Ahmed Elzoughary, Email: aelzoughary@gmail.com

Abstract

Background.

An esthetically acceptable ceramic restoration should have optical properties like the teeth and reflect, transmit, and absorb light. The present investigation compared how hydrothermal aging affected the properties of two types of zirconia and lithium disilicate.

Methods.

Thirty rectangular samples (12×14×1 mm) were prepared and sectioned from three different ceramic blocks/blanks (n=10), then assigned into three groups according to the ceramic type: group Z: IPS e.max ZirCAD prime, gradient zirconia (3Y/5Y-TZP); group K: Katana UTML (5Y-TZP); and group E: IPS e.max CAD (lithium disilicate). Color analysis of samples was performed before and after hydrothermal aging (1, 3, and 5 hours) using a spectrophotometer. Color difference (∆E00), translucency parameter (TP00), and contrast ratio (CR) were evaluated. The microstructural analysis was performed using x-ray diffraction (XRD). Data were statistically analyzed at a significance level of P<0.05.

Results.

A statistically significant variation was observed across means of ∆E00, TP00, and CR at different times. Group Z displayed the highest statistically significant mean ∆E00. Group E demonstrated the greatest statistically significant mean TP00. Group K exhibited the most statistically significant mean CR.

Conclusion.

Hydrothermal aging significantly affected the optical characteristics of lithium disilicate and zirconia ceramics. The translucency of samples increased with aging.

Keywords: Aging, Ceramics, Color, Lithium disilicate, Tooth discoloration, Zirconium oxide

Copyright and License Information

©2024 The Author(s).
This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Funding Statement

None.

Introduction

Due to the growing need for naturally appearing restorations, the superior aesthetics and biocompatibility of ceramic restorations are the critical reasons for their increasing popularity.1 Different ceramic systems, including lithium disilicate, zirconium oxide, and derivatives, have been introduced to dentistry to meet these demands.2-5 Lithium disilicate is suitable for esthetic rehabilitation because of its unique microstructure, which is essential to its optical and mechanical characteristics.6-9 However, to combine aesthetics with superior strength properties, the manufacturers of dental materials have produced highly translucent monolithic zirconia.10

Zirconia is a polycrystalline ceramic that is devoid of glass content. It is polymorphic in nature, meaning it can exist in three different shapes: cubic, tetragonal, and monoclinic. Pure zirconia exists in a monoclinic shape under ambient temperature, transforming to tetragonal at 1170 °C and cubic at 2370 °C. Volumetric change (approximately a 5% increase) coincides with the transition from monoclinic to tetragonal shape.11 The inclusion of stabilizing oxides, including yttrium, cerium, magnesium, and calcium oxides, helps stabilize zirconia in its tetragonal and cubic phases under ambient temperature.12 Yttrium oxide is the most commonly used stabilizer, where yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP) was demonstrated to have the most pronounced phase transformation toughening.13 Using 3 mol% yttria to stabilize zirconia (3Y-TZP) is the initially produced Y-TZP in dentistry. One drawback of this generation is its whitish opaque color; therefore, veneering porcelain was applied to the zirconia core to maximize its aesthetic possibility. The main problem encountered with zirconia-based restorations is the chipping of the veneering porcelain.14 In response to this issue, monolithic translucent zirconia was introduced to allow their use in a fully contoured condition.15,16

Several modifications were added to make zirconia suitable for monolithic restorations with adequate esthetics for anterior or posterior restorations. As part of this, the yttria concentration was raised from 3 mol% (3Y-TZP) to 4 mol% (4Y-TZP) and 5 mol% (5Y-TZP), in addition to introducing the polychromatic zirconia (multilayered).15,16 Another multilayered technique has recently been released, combining many zirconia generations into one blank to get the benefits of zirconia that is both conventional and ultra-translucent by combining the strong translucency of 5Y-TZP in the incisal/occlusal zone along with the elevated flexural strength of 3Y-TZP in the dentin/body zone to boost the stability.17

Translucency is one of the main characteristics of human dentition and is considered a crucial factor of dental restorative aesthetics. TP assesses the variation in light reflection across the specimen among a highly absorbent backdrop (black background) and a highly reflective backdrop (white background).18 The previous study demonstrated that the translucency of lithium disilicate was higher than that of 3Y-PSZ and 4Y-PSZ (4 mol% yttria partially stabilized zirconia), although it did not differ significantly from that of 5Y-PSZ.19 Color stability is necessary for cosmetic restorations to have long-term clinical success because it guarantees consistent color matching. Nevertheless, aging has an impact on dental ceramics’ translucency and color. It has been demonstrated that artificial aging by autoclave can cause some hydrothermal aging.20 Chevalier et al21 reported that autoclaving for one hour at 134 °C, in theory, is similar to 3‒4 years in a clinical setting. The esthetic success of new zirconia generations under hydrothermal aging or different oral conditions has not been adequately studied in the literature. As a result, the current study aimed to investigate whether hydrothermal aging affects the color, translucency, and contrast ratio (CR) of the examined materials. Consequently, the present research’s null hypothesis was that hydrothermal aging would not affect the color, translucency, and CR of tested materials (zirconia and lithium disilicate).


Methods

According to a previous investigation,22 the sample size needed for every group was established using Thompson’s power analysis test, with a confidence level of 95%, an α level of 0.05, and a β of 0.1. It was determined that 10 samples were needed for each group. Thirty samples were fabricated and divided into three groups (n = 10): group Z: IPS e.max ZirCAD prime, multilayered gradient zirconia (3Y/5Y-TZP) with highly translucent 5Y-TZP incisal zone, transition zone, 3Y-TZP cervical zone; group K: Katana Ultra Translucent multilayered zirconia UTML (5Y-TZP); and Group E: IPS e.max CAD (lithium disilicate glass-ceramic) (Tables 1 and 2; Figure 1).


Table 1. Materials used in the current study
Material Chemical Composition Manufacturer & Lot Number
IPS e.max ZirCAD prime (Z) ZrO2 88.0- 95.5%
Y2O3 > 4.5%- ≤ 7.0%
HfO2: ≤ 5.0%
Al2O3: ≤ 1.0%, Other oxides: ≤ 1.5%
Ivoclar Vivadent; Schaan, Liechtenstein
(Lot. Nr: Z00C8R)
Katana zirconia UTML (K) ZrO2 + HfO2: 87‒92%
Y2O3: 8‒11%, Other oxides: 0‒2%
Kurary, Noritake Dental Inc, Miyoshi-cho Miyoshi, Japan. (Lot. Nr: EKUUO)
IPS e.max CAD (E) 80% SiO2, 19% Li2O, 13% K2O, 11% P2O5, 8% ZrO2, 5% ZnO, 5% Al2O3, 8% MgO, coloring oxides 0‒12% Ivoclar Vivadent; Schaan, Liechtenstein
(Lot. Nr: Z019VN)

Table 2. Properties of the used materials
Properties IPS- e.max CAD Katana zirconia (UTML) IPS-e.maxZirCAD Prime
Flexural strength 360 ± 60 MPa 557 MPa 650‒850 MPa
Modulus of elasticity 95 ± 5 GPa 214‒217 GPa
Fracture toughness 2.0 - 2.5 MPa.m1/2 3.6 MPa. m1/2
Vickers hardness 5800 ± 200 MPa 1.280 HV10 23.03 ± 0.56 GPa
Coefficient of thermal expansion 10.15 ± 0.4 10-6 K-1
(100‒400°C)
9.7 × 10-6 K-1
(25‒500°C)
10.75 ± 0.25 × 10-6 K-1
(100‒400°C)
joddd-18-172-g001
Figure 1.

A schematic flow chart of the experimental procedure from A to K. (A) IPS e.max ZirCAD Prime and Katana zirconia preparation by Isomet. (B) Sintering of zirconia samples. (C) IPS e.max samples preparation by Isomet. (D) Crystallization of IPS e.max. (E) Digital calibration of all samples in final dimension (12 × 14 × 1 mm). (F) Polishing of samples using a customized device. (G) Ultrasonic cleaning up to 10 minutes and drying. (H) Spectrophotometer measurement before aging of samples in an autoclave. (I) Class B autoclave for aging times (1, 3, and 5 hours). (J) Spectrophotometer measurement after aging of samples. (K) X-ray diffraction for all samples before and after aging times (1, 3, and 5 hours).


Thirty rectangular samples with a final dimension of (12 × 14 × 1 mm in thickness)23 were sectioned using a low-speed diamond high-precision saw (Isomet 4000, Buehler Ltd, Lake Bluff, LL, USA) at 2500 rpm and under water coolant. Following cutting, a digital caliper (Mitutoyo 200 mm/8 inch, Absolute Digimatic Vernier Caliper, Japan) with an 0.01 mm accuracy was used to verify the samples’ thickness. Zirconia samples were sectioned 20% greater in size to compensate for shrinkage following sintering. Sintering of zirconia samples and crystallization of IPS e.max ceramic samples were achieved according to the manufacturer’s instructions for each type (Figure 2). Zirconia samples (groups Z and K) were sintered in a high-temperature sintering furnace (inFire HTC, Dentsply Sirona) according to the manufacturer’s instructions; group Z was sintered for 2 hours at 1500 °C, and group K was sintered at 1550 °C, with a holding time of 2 hours. IPS e.max CAD samples were crystallized using the Programat P3010 furnace (Programat EP-3010 Furnace, Ivoclar Vivadent) with the specific program for IPS e-max crystallization according to the manufacturer’s instructions (at a temperature of 840 °C and holding time of 7 minutes).

joddd-18-172-g002
Figure 2.

Katana and ZirCAD Prime Zirconia sintering, while e.max ceramic crystallization.


All the ceramic samples underwent hydrothermal aging using a class B autoclave, as per the guidelines of the International Organization for Standardization (ISO 13356:2015).24 The standard conditions involved maintaining a pressure of 0.2 MPa and a temperature of 134 °C for different durations: 0 (control), 1, 3, and 5 hours.24 It has been documented that autoclaving at a pressure of 0.2 MPa for 1 hour at 134 °C is comparable to a clinical setting lasting 3‒4 years.25

A spectrophotometer (Cary5000UV-Vis-NIRSpectrophotometer; Agilent Technologies USA.) was employed to determine L*a*b* color coordinates of all the samples regarding the CIEL*a*b* color scale before (baseline) and after hydrothermal aging (after 1, 3, and 5 hours).Before evaluating every sample’s color, the spectrophotometer was calibrated using an integrating sphere connection. L*a*b* coordinates of color were established via the CIEL*a*b* color scale using standard illuminant D65 and 10 degrees standard observer angle over white (L* = 99.85, a* = -0.01, b* = -0.15) and black (L* = 2.06, a* = -0.46, b* = 1.10) backgrounds. The samples were positioned in the middle of the measurement port and kept there for the two foundations, and the spectrophotometer remained in the same position during all the measurements. Within 5-nm periods, the relative reflectivity measurements were acquired in the visible wavelengths: between 380 and 780 nm.

The color difference (∆E00)of each sample was achieved by determining the sample’s color difference compared to a black (L* = 2.06, a* = -0.46, b* = 1.10) background before and after hydrothermal aging (after 1, 3, and 5 hours) using the following equation:26

ΔE00 = [(ΔL’/KLSL)2 + (ΔC’/KCSC)2 + (ΔH’/KHSH)2 + RT (ΔC’/KCSC) (ΔH’/KHSH)]1/2

The translucency parameter (TP00) values were assessed based on CIEDE2000 by measuring the color difference of each sample against black (L* = 2.06, a* = -0.46, b* = 1.10) and white (L* = 99.85, a* = -0.01, b* = -0.15) backgrounds before and after hydrothermal aging (after 1, 3, and 5 hours) using the following equation27:

ΔTP00 = [(ΔL’/KLSL)2 + (ΔC’/KCSC)2 + (ΔH’/KHSH)2 + RT (ΔC’/KCSC) (ΔH’/KHSH)]1/2

where ΔL’, ΔC’, and ΔH’ are the differences in the lightness, chroma, and hue of a given set of samples, respectively. KL, KC, and KH are parametric factors used to compensate for the mismatch in the experimental conditions; they were fixed at 1 in the current study. SL, SC, and SH correspond to the weighting functions for lightness, chroma, and hue, respectively. RT represents the rotation function, which is used to adjust for the interaction between the differences in chroma and hue in the blue region.27,28

The CR was evaluated using the following equation: CR=Yblack/Ywhite

where Yblack denotes the CIE tristimulus value of the sample against black (L* = 2.06, a* = -0.46, b* = 1.10) background, and Ywhite denotes the CIE tristimulus value of the sample against the white (L* = 99.85, a* = -0.01, b* = -0.15) background. High CR values (maximum of 1) are associated with opaque objects, while high values of TP are associated with translucent materials.

X-ray diffraction

X-ray diffraction (XRD, D8 Discover Plus, Burker, Germany)is a widely used method for figuring out a material’s crystalline makeup or composition. The levels of ceramics’ chemical components were assessed via wavelength dispersive x-ray fluorescence spectroscopy (WD-XRF; Bruker S8 Tiger, Germany) employing a 4 KW x-ray tube. XRD was accomplished for all the samples before and after different aging times (1, 3, and 5 hours.). Quant-Express software (Bruker, Karlsruhe, Germany) was used to automatically deliver the raw data on the chemical components of the samples.

Statistical analysis

The mean and standard deviation (SD) values were used to display numerical data. They were analyzed for normality and variance homogeneity by viewing the data distribution and using Shapiro-Wilk and Levene’s tests, respectively. The data were normally distributed, had homogenous variances, and were analyzed using two-way mixed-model ANOVA. A significant threshold of P < 0.05 was applied. R statistical analysis version 4.3.3 for Windows was used to analyze the statistics.


Results

Color difference (ΔE00)

Both material type and aging time significantly affected ΔE00 (P < 0.001), whereas the impact of the interaction between them was not statistically significant (P = 0.637) (Table 3, Figure 3).


Table 3. Effect of different variables and their interactions on color difference (ΔE00)
Variable Sum of squares (II) df Mean square f-value P value
Material 8.64 2 4.32 233.69  < 0.001*
Aging time 4.77 2 2.38 194.28  < 0.001*
Material × aging time 0.03 4 0.01 0.64 0.637ns

df = degree of freedom*; significant (P < 0.05) ns; non-significant (P ≥ 0.05).

joddd-18-172-g003
Figure 3.

A column chart displaying mean color change (ΔE00) values for various materials and aging times


The various materials differed significantly from one another (P < 0.001). After different aging times (1, 3, and 5 hours), the highest value was recorded in ZirCAD Prime (1.86 ± 0.12, 2.20 ± 0.11, and 2.41 ± 0.15, respectively), followed by Katana (1.33 ± 0.11, 1.72 ± 0.09, 1.95 ± 0.10, respectively). In contrast, the lowest value was recorded with IPS e.max (1.14 ± 0.11, 1.46 ± 0.11, and 1.64 ± 0.15, respectively) (Table 4).


Table 4. Intergroup and intragroup comparisons; mean and standard deviation (SD) values of color differences (ΔE00) for different materials and aging times
Aging time Color difference (ΔE00) (Mean±SD) P value
IPS e.max CAD ZirCAD Prime Katana UTML
1-hour aging 1.14 ± 0.11Cc 1.86 ± 0.12Ac 1.33 ± 0.11Bc  < 0.001*
3-hour aging 1.46 ± 0.11Cb 2.20 ± 0.11Ab 1.72 ± 0.09Bb  < 0.001*
5-hour aging 1.64 ± 0.15Ca 2.41 ± 0.15Aa 1.95 ± 0.10Ba  < 0.001*
P value  < 0.001*  < 0.001*  < 0.001*

Different uppercase superscripts indicate a statistically significant difference within the same horizontal row.

Different lowercase superscripts indicate a statistically significant difference within the same vertical column.

* Significant (P < 0.05), ns: non-significant (P ≥ 0.05).

After 1, 3, and 5 hours, a statistically significant difference (P < 0.001) was observed across the ΔE00 of ceramic types. The highest value was recorded after 5 hours of aging, followed by 3-hour aging, whereas the lowest value was recorded after 1 hour of aging. Every pairwise comparison made after the fact was statistically significant (P < 0.001).

Translucency parameter (TP00)

The findings indicated that the mean TP00 was significantly impacted (P < 0.001) by both ceramic type (independent of time) and aging time (independent of the ceramic type) (Table 5, Figure 4).


Table 5. Effect of different variables and their interactions on translucency parameter (TP00)
Variable Sum of Squares (II) df Mean Square f-value P value
Material 606.41 2 303.21 7386.82  < 0.001*
Aging time 14.47 2 6.73 526.96  < 0.001*
Material × aging time 0.62 4 0.14 11.33  < 0.001*

df = degree of freedom. * Significant (P < 0.05), ns: non-significant (P ≥ 0.05).

joddd-18-172-g004
Figure 4.

A column chart displaying mean translucency parameter (TP00) values for various materials and aging times


The various materials differed significantly from one another (P < 0.001). Along the different aging times (1, 3, and 5 hours), the greatest translucency was discovered in IPS e.max (11.63 ± 0.14, 11.94 ± 0.14, and 12.01 ± 0.15, respectively), followed by ZirCAD Prime (7.38 ± 0.13, 7.57 ± 0.14, and 7.71 ± 0.15, respectively). In contrast, the least translucency was discovered at Katana (6.53 ± 0.14, 6.83 ± 0.10, and 6.68 ± 0.11, respectively). Every pairwise comparison made after the fact was statistically significant (P < 0.001). Moreover, a statistically significant variation was displayed in the TP00 of ceramic types at baseline (before aging) and after 1, 3, and 5 hours. Post hoc pairwise comparisons showed the highest translucency after 5 hours of aging, followed by 3-hour aging, while the lowest translucency was related to before aging (Table 6).


Table 6. The repeated measurements’ mean, standard deviation (SD), and outcomes ANOVA test for TP00 comparisons of different ceramic materials and periods
Aging time Translucency parameter (TP00) (Mean±SD) P value
IPS e.max CAD ZirCAD Prime Katana UTML
Before aging 10.99 ± 0.13Ac 6.96 ± 0.11Bd 5.87 ± 0.11Cc  < 0.001*
1-hour aging 11.63 ± 0.14Ab 7.38 ± 0.13Bc 6.53 ± 0.14Cb  < 0.001*
3-hour aging 11.94 ± 0.14Aa 7.57 ± 0.14Bb 6.83 ± 0.10Ca  < 0.001*
5-hour aging 12.01 ± 0.15Aa 7.71 ± 0.15Ba 6.68 ± 0.11Cb  < 0.001*
P value  < 0.001*  < 0.001*  < 0.001*

Different uppercase superscripts indicate a statistically significant difference within the same horizontal row.

Different lowercase superscripts indicate a statistically significant difference within the same vertical column.

* Significant (P < 0.05), ns: non-significant (P ≥ 0.05).

Contrast ratio

There was a significant interaction between both tested variables (P < 0.001) (Table 7). For the IPS e.max group, the highest CR was found before aging (0.69 ± 0.00), followed by 1-hour aging (0.67 ± 0.00) and 3-hour aging (0.67 ± 0.00), while the lowest CR was found in 5-hour aging (0.66 ± 0.00). For the ZirCAD Prime group, the highest CR was found before aging (0.78 ± 0.00), followed by 1-hour aging (0.76 ± 0.00) and 3-hour aging (0.75 ± 0.01), while the lowest CR was found in 5-hour aging (0.75 ± 0.01). For the Katana group, the highest CR was found before aging (0.80 ± 0.00), followed by 1-hour aging (0.77 ± 0.01) and 5-hour aging (0.77 ± 0.00), while the lowest CR was found in 3-hour aging (0.76 ± 0.00). Post hoc pairwise comparisons showed a significantly higher CR before aging compared to other aging times (P < 0.001) (Table 8).


Table 7. Effect of different variables and their interactions on contrast ratio (CR)
Variable Sum of squares (II) df Mean square f-value P value
Material 0.24 2 0.12 2885.92  < 0.001*
Aging time 0.01 2 0.01 308.32  < 0.001*
Material × aging time 0.00 4 0.00 9.76  < 0.001*

df = degree of freedom. * Significant (P < 0.05), ns: non-significant (P ≥ 0.05).


Table 8. Intergroup and intragroup comparisons; mean and standard deviation (SD) values of contrast ratio (CR) for various materials and aging times
Aging time Contrast ratio (CR) (Mean±SD) P value
IPS e.max CAD ZirCAD Prime Katana UTML
Before aging 0.69 ± 0.00Ca 0.78 ± 0.00Ba 0.80 ± 0.00Aa  < 0.001*
1-hour aging 0.67 ± 0.00Cb 0.76 ± 0.00Bb 0.77 ± 0.01Ab  < 0.001*
3-hour aging 0.67 ± 0.00Cc 0.75 ± 0.01Bbc 0.76 ± 0.00Ac  < 0.001*
5-hour aging 0.66 ± 0.00Cc 0.75 ± 0.01Bc 0.77 ± 0.00Ab  < 0.001*
P value  < 0.001*  < 0.001*  < 0.001*

Different uppercase superscripts indicate a statistically significant difference within the same horizontal row.

Different lowercase superscripts indicate a statistically significant difference within the same vertical column.

* Significant (P < 0.05), ns: non-significant (P ≥ 0.05).

X-ray diffraction

Regarding XRD results, aging times resulted in tetragonal (t)/monoclinic (m) phase transformation in group Z (ZirCAD Prime, gradient zirconia)) only. However, no monoclinic phase transformation was detected in the 5Y (Katana), group K. For group E (IPS e.max CAD), composed mainly of Li2(Si2O5) and Li2(Si3O7) phases at different ratios, the main phase is Li2(Si2O5) crystalline phase in the material, which increased with increased aging time. Table 9 presents the crystal content of each material and crystal peak readings.


Table 9. XRD demonstrating crystalline content (%) for each material after different aging times
Group ZirCAD Prime Katana UTML
Control 1 hour 3 hours 5 hours Control 1 hour 3 hours 5 hours
Tetragonal % 66.2 51 47.9 53.7 60.3 61.1 58.1 57.5
Cubic % 33.8 28.5 29.2 30.4 39.7 38.9 41.9 42.5
Monoclinic % 0 20.5 22.9 15.9 0 0 0 0
IPS e.max CAD
Control 1 hour 3 hours 5 hours
Dilithium disilicate% 66.4 65.5 77 80.5
Dilithium closoheptaoxotrisilicate% 33.6 34.5 23 19.5

Discussion

An all-ceramic restoration that looks natural must be similar in color and translucency to natural teeth. Without veneering, lithium disilicate ceramics are appropriate for anterior and posterior crowns, thanks to their high optical properties and reasonable mechanical ones.29 The production of zirconia for dental prosthetic restorations has expanded during the last few years. Adding yttria to zirconia creates more cubic phases, enhancing translucency. Nevertheless, some tetragonal phases decrease the strength.12 Based on the current research’s findings, the null hypothesis was rejected as hydrothermal aging significantly impacted the ceramic samples’ optical characteristics.Analytical tools can be used to quantify color to obtain more accurate measurements of color.30 In the current research, the coordination of colors in CIE00 L*a*b* was evaluated using a spectrophotometer on flat ceramic samples (12 × 14 × 1 mm). Since this device might be less precise when evaluating a curved surface, this situation was irrelevant to the current investigation. Other multiple investigations confirmed the accuracy and validity of spectrophotometer in color measurement.31-33

Hydrothermal aging is the most popular technique for accelerating age; however, exposure to UV radiation and using water spray in a weathering device might be used, too.34,35 Hydrothermal aging in autoclaves is one of the most widely recognized techniques for simulating clinical settings. When portions of a material’s tetragonal zirconia phase are subjected to moisture or hydrothermal degradation, this might change the mechanical and optical characteristics of the zirconia subsurface and cause a t/m transition.36 In this research, the zirconia samples underwent polishing treatments, which are advised as a crucial clinical process to improve sample outcomes. According to Pereira et al,37 smoother surfaces may have less area for water interactions, making them less susceptible to hydrothermal aging. A 1-mm ceramic thickness was used as the standard recommended for monolithic zirconia restorations. According to Tabatabaian et al,23 a minimum thickness of 1 and 1.6 mm of zirconia coping is needed to hide the material to obtain appropriate tolerance and observable tolerance threshold correspondingly.

Various investigations have documented a color change in dental ceramics due to aging.9,38 In general, numerous variables influence the color of ceramic materials, including surface cracks, roughness, and method of sintering. Therefore, when temperature time increases, grain size increases, and porosity is reduced, the formation of a highly organized crystalline structure that permits light reflection might be the main factor affecting the color difference. Theoretically, thermal conditions may influence the coloring pigments that were put into Y-TZP ceramics, which led to pigment disintegration and instability of color.39 Nakamura et al14 demonstrated that, following autoclaving for 100 hours, ΔE values were under the perceptibility threshold despite LTD’s impact on the color characteristics of 3Y-TZP. Additionally, they discovered that the colored 3Y-TZP had a larger cubic fraction and greater quantities of trivalent dopants (Fe2O3 and Er2O3) than the noncolored zirconia, which resulted in higher resistance to LTD.

The color difference (ΔE00) of samples was assessed through perceptibility threshold “PT” of 50:50% (ΔE00 = 0.8) and acceptability threshold “AT” of 50:50% (ΔE00 = 1.8) according to Paravina et al.26 Greater ΔE00 value more than (0.8) (PT) is considered clinically perceptible, and a ΔE00 value higher than 1.8 (AT) is considered clinically unacceptable. While Salas et al27 determined the translucency perceptibility threshold (TPT00) = 0.62 units and the translucency acceptability threshold (TAT00) = 2.62 units.

All color measurements were significantly different in the present research regardless of ceramic type or aging time. Group Z showed the highest mean ΔE00, followed by groups K and E. When exposed to ambient temperature and humidity, stabilized zirconia polycrystals undergo a degradation process known as low-temperature degradation (LTD) aging, during which stabilizing oxides are removed from the substance’s structure. This results in a crack, damage to structural integrity, and a reduction in the mechanical characteristics of the material by causing the tetragonal-to-monoclinic phase transformation. Furthermore, the alumina concentration was reduced in monolithic zirconia to increase translucency. The resistance to deterioration at low temperatures is ascribed to alumina. Consequently, monolithic zirconia can be more vulnerable to LTD.40

In the present research, with increasing aging time, a significant color change of the ceramic sample (ΔE00) was noted, which was still within the clinically acceptable range, except for group Z after 3 and 5 hours and group K after 5 hours. Various studies have shown that following artificially accelerated aging, zirconia had a much greater color shift than lithium disilicate.41,42 Kim et al42 showed that after autoclave-based artificial aging at 134 °C at 0.2 MPa for 0, 1, 3, 5, or 10 hours, Katana monolithic zirconia displayed a significantly greater color change than IPS e.max CAD, which might be attributed to the low a* and b* values and high L* values. Unlike the current outcomes, Subaşı et al43 showed non-significant variations in the color change values between three CAD-CAM monolithic ceramic materials. Following 5000 thermocycles in a coffee solution, the three materials (Vita Suprinity PC, IPS e.max CAD, and InCoris TZI C) had identical thicknesses. Inconsistencies in research findings may be due to the differences in sample preparation and aging techniques.

Translucency is one of the main determining elements and an important one when choosing. The present study documented an increase in TP and a reduction in CR. Group E was the most translucent with the lowest CR, which concurs with many earlier examinations.4,5,7,44 This may be explained by the lithium disilicate glass content. When evaluated at the identical thickness, the translucency of recent types of monolithic zirconia remains less than that of lithium disilicate, although a significant enhancement in comparison to traditional ones.44,45

The findings of the present research agreed with Kim et al,42 who evaluated the impact of hydrothermal aging on the optical characteristics of pre-colored monolithic zirconia ceramics and demonstrated that the aging by hydrothermal means impacted its optical qualities and the translucency increased with a longer aging period. Additionally, with longer aging times, greater TP values might be obtained due to particular metal oxides in coloring pigments, promoting the microstructure-level production of cubic zirconia. However, according to the findings of the XRD of the present research, there was no increase in cubic zirconia after aging time, so these changes were attributed to other factors such as the aging process, roughness, and porosity.

Since various zirconia materials include varying concentrations of Y2O3, Al2O3, and other oxides, they display varying translucencies. As dopants, metal oxides disperse incident rays and reflect light. Perhaps increased translucency results from the dopant separation of trivalent ions to the grain boundaries, which boosts hydrothermal stability.46 Zhang47 introduced 0.2% mole La2O3 in traditional Al2O3-doped 3Y-TZP, yielding good mechanical characteristics, lack of LTD, and translucency similar to lithium disilicate. This co-doping of La2O3 and Al2O3 caused the whole dissolving of La2O3 in the zirconia grains devoid of the formation of a secondary phase, which is what gave the material its increased translucency and resistance to LTD. However, these results did not agree with Ahmed et al,48 who assessed the influence of artificial aging on the ultra-translucent tetragonal/cubic zirconia’s optical characteristics (53% cubic and 47% tetragonal). They demonstrated no significant change in the translucency after rapid autoclave treatment for one or three hours. Their results were supported by the significant quantity of cubic phase, which renders the zirconia stable in hydrothermal conditions. Volpato et al49 also assessed the color and translucency of zirconia that had been artificially aged in a steam autoclave for four hours and showed no alteration in translucency in any of the samples, either before or after a coloring liquid was applied.

CR has been used to assess a material’s opacity. TP is more commonly used in literature than CR. Spink et al50 stated that CR, an indicator of diffuse reflectance, cannot identify minute variations in light transmission if materials have large scattering and absorption coefficients. Samples with more TP values and less CR values exhibit more translucency or less opacity.51

The ISO standard 13 356:2008 states that for appropriate biomedical usage, the maximum quantity of Y-TZP monoclinic phase following autoclaving and aging at 134°C under 0.2 MPa for five hours should not exceed 25%.24 In the present investigation, group Z showed greater t/m transition behavior as the aging period increased, causing 20.5% of m-phase at 1 hour and 22.9% at 3 hours of artificial aging. Quantification of crystalline structures is commonly achieved by employing the XRD technique. Crystal peak readings may be used to readily define the phenomena of t/m transformation and alterations in the lattice position against the transport of atoms.52

Regarding XRD results, aging times caused the phase transformation between tetragonal (t) and monoclinic (m) for the (ZirCAD Prime) group Z only, which explains the quantity of yttria and how it relates to toughening transformation. Generally, zirconia with less yttria has more tetragonal particles that can change into monoclinic. However, there was no formation of monoclinic phase transformation in the 5Y (Katana) group K. Due to the high yttria concentration, 5Y zirconia has a high stability, which might account for the absence of phase transformation. At the same time, in group E (IPS e.max), composed of Li2(Si2O5) and Li2 (Si3O7) phases at different ratios, the main phase is the Li2(Si2O5) crystalline phase in the material, which increased with increased aging time.The limitation of the present research was that samples used only one thickness for all types of ceramics under one type of aging. However, dental restorations in the oral environment are subjected to numerous stimuli, such as mechanical aging and pH fluctuations. Further research is thus needed to evaluate the alterations in the optical characteristics of dental ceramics considering different aging circumstances to represent the clinical setting.


Conclusion

Considering the constraints of the present research, the subsequent conclusions can be noted:

  1. All the ceramic groups displayed a significant change in the optical properties following hydrothermal aging.

  2. Translucency increased with increasing hydrothermal aging time.

  3. ZirCAD Prime gradient zirconia was more translucent with aging than the Katana type.


Competing Interests

The authors declared no conflicts of interest.


Ethics Approval

The research proposal was approved by Research Ethics Committee of the Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt (No: 578/2600).


References

  1. Sailer I, Balmer M, Hüsler J, Hämmerle CH, Känel S, Thoma DS. 10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses. J Dent 2018; 76:32-9. doi: 10.1016/j.jdent.2018.05.015 [Crossref] [ Google Scholar]
  2. Amarante JE, Soares Pereira MV, De Souza GM, Pais Alves MF, Simba BG, Dos Santos C. Effect of hydrothermal aging on the properties of zirconia with different levels of translucency. J Mech Behav Biomed Mater 2020; 109:103847. doi: 10.1016/j.jmbbm.2020.103847 [Crossref] [ Google Scholar]
  3. Zhang F, Inokoshi M, Batuk M, Hadermann J, Naert I, Van Meerbeek B. Strength, toughness and aging stability of highly-translucent Y-TZP ceramics for dental restorations. Dent Mater 2016; 32(12):e327-37. doi: 10.1016/j.dental.2016.09.025 [Crossref] [ Google Scholar]
  4. Ziyad TA, Abu-Naba’a LA, Almohammed SN. Optical properties of CAD-CAM monolithic systems compared: three multi-layered zirconia and one lithium disilicate system. Heliyon 2021; 7(10):e08151. doi: 10.1016/j.heliyon.2021.e08151 [Crossref] [ Google Scholar]
  5. Reale Reyes A, Dennison JB, Powers JM, Sierraalta M, Yaman P. Translucency and flexural strength of translucent zirconia ceramics. J Prosthet Dent 2023; 129(4):644-9. doi: 10.1016/j.prosdent.2021.06.019 [Crossref] [ Google Scholar]
  6. Kurt M, Bankoğlu Güngör M, Karakoca Nemli S, Turhan Bal B. Effects of glazing methods on the optical and surface properties of silicate ceramics. J Prosthodont Res 2020; 64(2):202-9. doi: 10.1016/j.jpor.2019.07.005 [Crossref] [ Google Scholar]
  7. Harada K, Raigrodski AJ, Chung KH, Flinn BD, Dogan S, Mancl LA. A comparative evaluation of the translucency of zirconias and lithium disilicate for monolithic restorations. J Prosthet Dent 2016; 116(2):257-63. doi: 10.1016/j.prosdent.2015.11.019 [Crossref] [ Google Scholar]
  8. Kwon SJ, Lawson NC, McLaren EE, Nejat AH, Burgess JO. Comparison of the mechanical properties of translucent zirconia and lithium disilicate. J Prosthet Dent 2018; 120(1):132-7. doi: 10.1016/j.prosdent.2017.08.004 [Crossref] [ Google Scholar]
  9. Aljanobi G, Al-Sowygh ZH. The effect of thermocycling on the translucency and color stability of modified glass ceramic and multilayer zirconia materials. Cureus 2020; 12(2):e6968. doi: 10.7759/cureus.6968 [Crossref] [ Google Scholar]
  10. Palla ES, Kontonasaki E, Kantiranis N, Papadopoulou L, Zorba T, Paraskevopoulos KM. Color stability of lithium disilicate ceramics after aging and immersion in common beverages. J Prosthet Dent 2018; 119(4):632-42. doi: 10.1016/j.prosdent.2017.04.031 [Crossref] [ Google Scholar]
  11. Ban S. Classification and properties of dental zirconia as implant fixtures and superstructures. Materials (Basel) 2021; 14(17):4879. doi: 10.3390/ma14174879 [Crossref] [ Google Scholar]
  12. Bachhav VC, Aras MA. Zirconia-based fixed partial dentures: a clinical review. Quintessence Int 2011; 42(2):173-82. [ Google Scholar]
  13. Stawarczyk B, Ozcan M, Hallmann L, Ender A, Mehl A, Hämmerlet CH. The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio. Clin Oral Investig 2013; 17(1):269-74. doi: 10.1007/s00784-012-0692-6 [Crossref] [ Google Scholar]
  14. Nakamura K, Harada A, Ono M, Shibasaki H, Kanno T, Niwano Y. Effect of low-temperature degradation on the mechanical and microstructural properties of tooth-colored 3Y-TZP ceramics. J Mech Behav Biomed Mater 2016; 53:301-11. doi: 10.1016/j.jmbbm.2015.08.031 [Crossref] [ Google Scholar]
  15. Schwindling FS, Waldecker M, Rammelsberg P, Rues S, Bömicke W. Tooth substance removal for ceramic single crown materials-an in vitro comparison. Clin Oral Investig 2019; 23(8):3359-66. doi: 10.1007/s00784-018-2753-y [Crossref] [ Google Scholar]
  16. Schönhoff LM, Lümkemann N, Buser R, Hampe R, Stawarczyk B. Fatigue resistance of monolithic strength-gradient zirconia materials. J Mech Behav Biomed Mater 2021; 119:104504. doi: 10.1016/j.jmbbm.2021.104504 [Crossref] [ Google Scholar]
  17. Michailova M, Elsayed A, Fabel G, Edelhoff D, Zylla IM, Stawarczyk B. Comparison between novel strength-gradient and color-gradient multilayered zirconia using conventional and high-speed sintering. J Mech Behav Biomed Mater 2020; 111:103977. doi: 10.1016/j.jmbbm.2020.103977 [Crossref] [ Google Scholar]
  18. Almohammed SN, Alshorman B, Abu-Naba’a LA. Optical properties of five esthetic ceramic materials used for monolithic restorations: a comparative in vitro study. Ceramics 2022; 5(4):961-80. doi: 10.3390/ceramics5040069 [Crossref] [ Google Scholar]
  19. Yan J, Kaizer MR, Zhang Y. Load-bearing capacity of lithium disilicate and ultra-translucent zirconias. J Mech Behav Biomed Mater 2018; 88:170-5. doi: 10.1016/j.jmbbm.2018.08.023 [Crossref] [ Google Scholar]
  20. Putra A, Chung KH, Flinn BD, Kuykendall T, Zheng C, Harada K. Effect of hydrothermal treatment on light transmission of translucent zirconias. J Prosthet Dent 2017; 118(3):422-9. doi: 10.1016/j.prosdent.2016.10.024 [Crossref] [ Google Scholar]
  21. Chevalier J, Olagnon C, Fantozzi G. Subcritical crack propagation in 3Y‐TZP ceramics: static and cyclic fatigue. J Am Ceram Soc 1999; 82(11):3129-38. doi: 10.1111/j.1151-2916.1999.tb02213.x [Crossref] [ Google Scholar]
  22. Elkhishen EA, Al-Zordk W, Hassouna M, Elsherbini A, Sakrana AA. Effect of ceramic and resin cement type on color stability and translucency of ceramic laminate veneers for diastema closure: an in vitro study. Sci Rep 2022; 12(1):22082. doi: 10.1038/s41598-022-26581-5 [Crossref] [ Google Scholar]
  23. Tabatabaian F, Dalirani S, Namdari M. Effect of thickness of zirconia ceramic on its masking ability: an in vitro study. J Prosthodont 2019; 28(6):666-71. doi: 10.1111/jopr.12625 [Crossref] [ Google Scholar]
  24. International Organization for Standardization (ISO). ISO 13356:2015. Implants for Surgery: Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia (YTZP). Geneva: ISO; 2015.
  25. Siarampi E, Kontonasaki E, Andrikopoulos KS, Kantiranis N, Voyiatzis GA, Zorba T. Effect of in vitro aging on the flexural strength and probability to fracture of Y-TZP zirconia ceramics for all-ceramic restorations. Dent Mater 2014; 30(12):e306-16. doi: 10.1016/j.dental.2014.05.033 [Crossref] [ Google Scholar]
  26. Paravina RD, Ghinea R, Herrera LJ, Bona AD, Igiel C, Linninger M. Color difference thresholds in dentistry. J Esthet Restor Dent 2015; 27 Suppl 1:S1-9. doi: 10.1111/jerd.12149 [Crossref] [ Google Scholar]
  27. Salas M, Lucena C, Herrera LJ, Yebra A, Della Bona A, Pérez MM. Translucency thresholds for dental materials. Dent Mater 2018; 34(8):1168-74. doi: 10.1016/j.dental.2018.05.001 [Crossref] [ Google Scholar]
  28. Yılmaz Savaş T, Aykent F. Effect of fabrication techniques on the optical properties of zirconia-based systems. J Prosthet Dent 2021;125(3):528.e1-528.e8. 10.1016/j.prosdent.2020.10.012.
  29. Phark JH, Duarte S Jr. Microstructural considerations for novel lithium disilicate glass ceramics: a review. J Esthet Restor Dent 2022; 34(1):92-103. doi: 10.1111/jerd.12864 [Crossref] [ Google Scholar]
  30. Bagheri R, Burrow MF, Tyas M. Influence of food-simulating solutions and surface finish on susceptibility to staining of aesthetic restorative materials. J Dent 2005; 33(5):389-98. doi: 10.1016/j.jdent.2004.10.018 [Crossref] [ Google Scholar]
  31. Liu MC, Aquilino SA, Lund PS, Vargas MA, Diaz-Arnold AM, Gratton DG. Human perception of dental porcelain translucency correlated to spectrophotometric measurements. J Prosthodont 2010; 19(3):187-93. doi: 10.1111/j.1532-849X.2009.00542.x [Crossref] [ Google Scholar]
  32. Yu B, Lee YK. Color difference of all-ceramic materials by the change of illuminants. Am J Dent 2009; 22(2):73-8. [ Google Scholar]
  33. Johnston WM, Hesse NS, Davis BK, Seghi RR. Analysis of edge-losses in reflectance measurements of pigmented maxillofacial elastomer. J Dent Res 1996; 75(2):752-60. doi: 10.1177/00220345960750020401 [Crossref] [ Google Scholar]
  34. Dikicier S, Ayyildiz S, Ozen J, Sipahi C. Effect of varying core thicknesses and artificial aging on the color difference of different all-ceramic materials. Acta Odontol Scand 2014; 72(8):623-9. doi: 10.3109/00016357.2013.879997 [Crossref] [ Google Scholar]
  35. Papageorgiou-Kyrana A, Kokoti M, Kontonasaki E, Koidis P. Evaluation of color stability of preshaded and liquid-shaded monolithic zirconia. J Prosthet Dent 2018; 119(3):467-72. doi: 10.1016/j.prosdent.2017.04.015 [Crossref] [ Google Scholar]
  36. Chevalier J, Gremillard L, Deville S. Low-temperature degradation of zirconia and implications for biomedical implants. Annu Rev Mater Res 2007; 37:1-32. doi: 10.1146/annurev.matsci.37.052506.084250 [Crossref] [ Google Scholar]
  37. Pereira GK, Venturini AB, Silvestri T, Dapieve KS, Montagner AF, Soares FZM. Low-temperature degradation of Y-TZP ceramics: a systematic review and meta-analysis. J Mech Behav Biomed Mater 2015; 55:151-63. doi: 10.1016/j.jmbbm.2015.10.017 [Crossref] [ Google Scholar]
  38. Mina NR, Baba NZ, Al-Harbi FA, Elgezawi MF, Daou M. The influence of simulated aging on the color stability of composite resin cements. J Prosthet Dent 2019; 121(2):306-10. doi: 10.1016/j.prosdent.2018.03.014 [Crossref] [ Google Scholar]
  39. Gonuldas F, Yılmaz K, Ozturk C. The effect of repeated firings on the color change and surface roughness of dental ceramics. J Adv Prosthodont 2014; 6(4):309-16. doi: 10.4047/jap.2014.6.4.309 [Crossref] [ Google Scholar]
  40. Bergamo E, da Silva WJ, Cesar PF, Del Bel Cury AA. Fracture load and phase transformation of monolithic zirconia crowns submitted to different aging protocols. Oper Dent 2016; 41(5):E118-30. doi: 10.2341/15-154-l [Crossref] [ Google Scholar]
  41. Haralur SB, Raqe SA, Alhassan Mujayri F. Effect of hydrothermal aging and beverages on color stability of lithium disilicate and zirconia-based ceramics. Medicina (Kaunas) 2019; 55(11):749. doi: 10.3390/medicina55110749 [Crossref] [ Google Scholar]
  42. Kim HK, Kim SH. Effect of hydrothermal aging on the optical properties of precolored dental monolithic zirconia ceramics. J Prosthet Dent 2019; 121(4):676-82. doi: 10.1016/j.prosdent.2018.06.021 [Crossref] [ Google Scholar]
  43. Subaşı MG, Alp G, Johnston WM, Yilmaz B. Effect of thickness on optical properties of monolithic CAD-CAM ceramics. J Dent 2018; 71:38-42. doi: 10.1016/j.jdent.2018.01.010 [Crossref] [ Google Scholar]
  44. Kurt M, Turhan Bal B. Effects of accelerated artificial aging on the translucency and color stability of monolithic ceramics with different surface treatments. J Prosthet Dent 2019;121(4):712.e1-712.e8. 10.1016/j.prosdent.2019.01.014.
  45. Vichi A, Sedda M, Fabian Fonzar R, Carrabba M, Ferrari M. Comparison of contrast ratio, translucency parameter, and flexural strength of traditional and “augmented translucency” zirconia for CEREC CAD/CAM system. J Esthet Restor Dent 2016; 28 Suppl 1:S32-9. doi: 10.1111/jerd.12172 [Crossref] [ Google Scholar]
  46. Papageorgiou-Kyrana K, Fasoula M, Kontonasaki E. Translucency of monolithic zirconia after hydrothermal aging: a review of in vitro studies. J Prosthodont 2020; 29(6):489-500. doi: 10.1111/jopr.13174 [Crossref] [ Google Scholar]
  47. Zhang Y. Making yttria-stabilized tetragonal zirconia translucent. Dent Mater 2014; 30(10):1195-203. doi: 10.1016/j.dental.2014.08.375 [Crossref] [ Google Scholar]
  48. Ahmed D, Mandour MH, El-Sharkawy Z. Optical properties and flexural strength of artificially aged tetragonal/cubic ultra-translucent zirconia. Al-Azhar Dent J Girls 2020; 7(1):135-42. doi: 10.21608/adjg.2019.9681.1123 [Crossref] [ Google Scholar]
  49. Volpato CA, Carvalho ÓS, da Cunha Pereira MR, Correia Pereira da Silva FS. Evaluation of the color and translucency of glass-infiltrated zirconia based on the concept of functionally graded materials. J Prosthet Dent 2019;121(3):547.e1-547.e7. 10.1016/j.prosdent.2018.09.019.
  50. Spink LS, Rungruanganut P, Megremis S, Kelly JR. Comparison of an absolute and surrogate measure of relative translucency in dental ceramics. Dent Mater 2013; 29(6):702-7. doi: 10.1016/j.dental.2013.03.021 [Crossref] [ Google Scholar]
  51. Della Bona A, Nogueira AD, Pecho OE. Optical properties of CAD-CAM ceramic systems. J Dent 2014; 42(9):1202-9. doi: 10.1016/j.jdent.2014.07.005 [Crossref] [ Google Scholar]
  52. Ali A, Chiang YW, Santos RM. X-ray diffraction techniques for mineral characterization: a review for engineers of the fundamentals, applications, and research directions. Minerals 2022; 12(2):205. doi: 10.3390/min12020205 [Crossref] [ Google Scholar]
Submitted: 20 Apr 2024
Accepted: 06 Jul 2024
First published online: 07 Sep 2024
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - FireFox Plugin)

Abstract View: 328
PDF Download: 236
Full Text View: 28