Logo-joddd

Visual Abstract

JODDD now with visual abstracts. Authors can now add a visual abstract to their submission.

Platinum* Open Access

*This Platinum Open Access journal publishes articles totally free of charge for the authors and provides unrestricted access to the published content through its website and open access repositories such as PubMed Central.

  Indexing & Abstracting

Following


Social media

J Dent Res Dent Clin Dent Prospects. 2016;10(3): 181-188. doi: 10.15171/joddd.2016.029
PMID: 27651885        PMCID: PMC5025220

Original Research

Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

Hadi Mokhtarpour 1, Reza Eftekhar Ashtiani 2, Minoo Mahshid 3, Farhad Tabatabaian 4 * , Marzieh Alikhasi 5

Cited by CrossRef: 9


1- Asli H, Falahchai M, Rahimabadi S, Arbab H, Mousavi Mehr Z. Abutment Screw Loosening in Single Implant Restorations: Evaluation of Fracture Strength of Implant-Supported Cement-Retained Monolithic Zirconia Restorations Repaired with Porcelain and Composite Resin. Dent Hypotheses. 2021;12(3):128 [Crossref]
2- Sahebi S, Giti R, Sherafati A, Azadi M. The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations. PLoS ONE. 2022;17(6):e0270527 [Crossref]
3- Saboury A, Mahshid M, Tabatabaian F, Moghadam L. Effect of screw access hole design on the fracture resistance of implant‐supported zirconia‐based restorations. J Esthet Restor Dent. 2018;30(6):545 [Crossref]
4- Nejat A, Dupree P, Kee E, Xu X, Zakkour W, Odom M, Bruggers K, Mascarenhas F. Effect of Endodontic Access Preparation on Fracture Load of Translucent versus Conventional Zirconia Crowns with Varying Occlusal Thicknesses. Journal of Prosthodontics. 2021;30(8):706 [Crossref]
5- Du L, Li Z, Chang X, Rahhal O, Qin B, Wen X, Zhou D. Effects of the Screw-Access Hole Diameter on the Biomechanical Behaviors of 4 Types of Cement-Retained Implant Prosthodontic Systems and Their Surrounding Cortical Bones. 2018;27(5):555 [Crossref]
6- Zhang S, Cheng Q, Wei M, Zhu Y, Han Y, Chen Y, Wang R, Chen C, Zhou H. Effect of screw access hole on the fracture load of implant-supported monolithic zirconia single crown. Advances in Applied Ceramics. 2022;121(1):1 [Crossref]
7- Talay Çevlik E, Alkan Demetoğlu G, Yıldız P. Effect of Vent Hole and Cement Type on Fracture Resistance of CAD‐CAM Monolithic Zirconia Crowns. Journal of Prosthodontics. 2023;32(5):411 [Crossref]
8- Ahmadi Y, Koodaryan R, Hafezeqoran A. Effect of the Diameter and Preparation Method of the Occlusal Screw Access Channel on Fracture Resistance of Cement-retained Implant-supported Posterior Monolithic Zirconia Crowns. TODENTJ. 2023;17(1) [Crossref]
9- Özcan M, Malpartida-Carrillo V, Ortiz-Culca F, Guerrero M, Amaya-Pajares S, Tinedo-López P. Fracture Resistance of Cement-retained, Screw-retained, and Combined Cement- and Screw-retained Metal-ceramic Implant-supported Molar Restorations . 2020;21(8):868 [Crossref]
10- Rasaie V, Abduo J, Falahchai M. Clinical and Laboratory Outcomes of Angled Screw Channel Implant Prostheses: A Systematic Review. Eur J Dent. 2022;16(03):488 [Crossref]