Logo-joddd

Visual Abstract

JODDD now with visual abstracts. Authors can now add a visual abstract to their submission.

Platinum* Open Access

*This Platinum Open Access journal publishes articles totally free of charge for the authors and provides unrestricted access to the published content through its website and open access repositories such as PubMed Central.

  Indexing & Abstracting

Following

Social media

J Dent Res Dent Clin Dent Prospects. 2018;12(3): 208-212. doi: 10.15171/joddd.2018.032
PMID: 30443307        PMCID: PMC6231151

Original Article

Comparison of cyclic fatigue resistance of XP-endo Shaper, HyFlex CM, FlexMaster and Race instruments

Mehmet Adiguzel 1 * , Ipek Isken 1, Ismail Ilker Pamukcu 1

Cited by CrossRef: 7


1- Tanomaru A, Limoeiro A, de Jesus Soares A, Junior E, Campos G, Hamasaki S, Nascimento W, Horta L, Goulart P, do Couto V, Alves P, Magalhães V, Campos D, Frozoni M. Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments. Eur J Dent. 2022;16(03):580 [Crossref]
2- Faus-Llácer V, Hamoud-Kharrat N, Marhuenda Ramos M, Faus-Matoses I, Zubizarreta-Macho Á, Ruiz Sánchez C, Faus-Matoses V. Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study. JCM. 2021;10(20):4713 [Crossref]
3- Adiguzel M, Tufenkci P, Pamukcu I. Comparison of postoperative pain intensity following the use of three different instrumentation techniques: A randomized clinical trial. J Dent Res Dent Clin Dent Prospects. 2019;13(2):133 [Crossref]
4- de Carvalho K, Petean I, Silva‐Sousa A, de Camargo R, Mazzi‐Chaves J, Silva‐Sousa Y, Sousa‐Neto M. Impact of several NiTi‐thermally treated instrumentation systems on biomechanical preparation of curved root canals in extracted mandibular molars. Int Endodontic J. 2022;55(1):124 [Crossref]
5- Kumar U, Parmar P, Vashisht R, Tandon N, Kaur C. Incidence of postoperative pain after using single continuous, single reciprocating, and full sequence continuous rotary file system: a prospective randomized clinical trial. J Dent Anesth Pain Med. 2023;23(2):91 [Crossref]
6- Alkahtany S, Alfadhel R, AlOmair A, Durayhim S, Kum K. Characteristics and Effectiveness of XP‐Endo Files and Systems: A Narrative Review. International Journal of Dentistry. 2024;2024(1) [Crossref]
7- Pedullà E, Canova F, La Rosa G, Naaman A, Diemer F, Generali L, Nehme W. Influence of NiTi Wire Diameter on Cyclic and Torsional Fatigue Resistance of Different Heat-Treated Endodontic Instruments. Materials. 2022;15(19):6568 [Crossref]